Clack MTM® is used for reducing iron, manganese and hydrogen sulfide from water supplies.

MTM®


        Clack MTM® is a granular manganese dioxide filtering media used for reducing iron, manganese and hydrogen sulfide from water. Its active surface coating oxidizes and precipitates soluble iron and manganese. Hydrogen sulfide is oxidized to a sulfur. The precipitates are filtered out in the granular bed and removed by backwashing.
        MTM consists of a light weight granular core with a coating of manganese dioxide. The coating provides an example of contact filtration where the media itself provides the oxidizing potential. This allows for a much broader range of operation than many other iron removal medias. A pH level as low as 6.2 can be treated. Dissolved oxygen is not essential. The media's light weight reduces backwash water requirements.
        When the oxidizing power of MTM is reduced, the bed has to be regenerated with a weak solution of potassium permanganate (KMnO4), thus restoring its oxidizing capacity. A regenerating solution of 1˝ to 2 ounces (dry
weight) of potassium permanganate per cubic foot is sufficient for normal regeneration. Upon start-up a new bed should be backwashed and caution taken to insure that the lightweight media is not backwashed to drain. A new bed should be regenerated the evening of installation. Operating the filter after its oxidizing capacity is exhausted will reduce its service life and may cause staining.
        MTM requires either intermittent or continuous regeneration to maintain its oxidizing capacity. A solution of potassium permanganate (or chlorine then
potassium permanganate) can be pre-fed to maintain capacity. In the latter case, the manganese dioxide coating acts as a catalyst to enhance the oxidation reaction and as a buffer to reduce any excess potassium permanganate concentration and prevent it from entering the service lines.

ADVANTAGES
 Broad operating range for iron reduction
 Lower pressure loss through the bed with high flock holding capacity
 Effective hydrogen sulfide, iron and manganese reduction.
 Light weight requires lower backwash rates and reduces pumping requirements

 Chlorine can be beneficial in extending filter run times
 Low attrition loss for long bed life
 Lower shipping cost


PHYSICAL PROPERTIES
 Color: Dark brown
 Bulk Density: 27 lbs./cu. ft.
 Specific Gravity: 1.7 gm/cc
 Effective Size: 0.6-0.7 mm
 Uniformity Coefficienty: 1.9
 Mesh Size: 12 x 35


CONDITIONS FOR OPERATION
 Water pH range: 6.2-8.5
 Maximum water temp: 100°F/38°C
 Bed depth: 24-36 in.
 Freeboard: 50% of bed depth (min.)
 Service flow rate: 3-5 gpm/sq. ft. continuous
 Backwash flow rate: 8-10 gpm per sq. ft.
 Backwash expansion rate: 20-40% of bed depth (min.)
 Regenerant dosage: 1˝-2 oz of KMnO4 by weight per cu. ft.


INFLUENT LIMITATIONS
Oil: None
Polyphosphates: None


CAPACITY PER CU. FT.
Iron (Fe+2) alone
   600 grains (10,000 ppm)
Manganese (Mn+2) alone
   300 grains (5,000 ppm)
Hydrogen Sulfide (H2S) alone
   175 grains (3,000 ppm)

MtmWMF0.GIF (8646 bytes)

Nsflogo.GIF (2926 bytes) ullogo.GIF (4834 bytes)

Tested and listed under ANSI/NSF Standard 61 for Health Effects.

Drinking Water Treatment System
Components Classified by
Underwriters Laboratories Inc.® in

Accordance with Standard
ANSI/NSF 61-(1991)-57Y3



Cclogo.GIF (1751 bytes)

Clack.GIF (6416 bytes)

MTM® is a federally registered trademark of ClackCorporation.

The information and recommendations in this publication are based on data we believe to be reliable. They are offered in good faith, but do not imply any warranty or performance guarantee, as conditions and methods of use of our products are beyond our control. As such, Clack makes no express or implied warranties of any kind with respect to this product, including but not limited to any implied warranty of merchantability or fitness for a particular purpose. We recommend that the user determine whether the products and the information given are appropriate, and the suitability and performance of our
products are appropriate, by testing with its own equipment.

The information and recommendations given in this publication should not be understood as recommending the use of our products in violation of any patent or as a license to use any patents of the Clack Corporation.

The filter medias listed in this brochure do not remove or kill bacteria. Do not use with water that is
microbiologically unsafe or of unknown quality withoutadequate disinfection before or after the system.

Clack will not be liable under any circumstance for consequential or incidental damages, including but not limited to, lost profits resulting from the use of our products.


[Home] [Profile] [Residential] [Commercial] [Components] [Dealer]
[Quick Quote] [E-mail us] [Search] [What's New]


animated_email9c.gif (20906 bytes)

R&M Manufacturing, Inc.   28 South 1550 West, Lindon UT 84042
Tele:(801)785-5557  Fax:(801)785-7823

Copyright ©  R&M Manufacturing, Inc. 1998